Monday, May 9, 2016

This is a highly scientific paper written by three mechanical engineers who are members of Architects and Engineers for 9/11 Truth. One is American; one is Canadian; and the third is Australian. It was first published in the International Journal of Protective Structures. 

It involves very high-level Mathematics that is certainly over the heads of most people. But, the gist of it is that even assuming "perfectly frangible columns" (and there is no reason to assume that) the shortest the collapse time could have been (even theoretically) was 15.3 seconds, and the Towers fell much more rapidly than that. Therefore, the "progressive column failure" theory of NIST is not viable. Truth is rising. 




Some Misunderstandings Related to WTC
Collapse Analysis
by
Gregory Szuladzin’ ski, Anthony Szamboti and Richard Johns

Reprinted from
International Journal of
Protective Structures
Volume 4 · Number 2 · June 2013
Multi-Science Publishing
ISSN 2041-4196
Some Misunderstandings Related to WTC
Collapse Analysis
Gregory Szuladzin’ski1,*, Anthony Szamboti2 and Richard Johns3
1FIEAust, Analytical Service Pty Ltd, Northbridge 2063, Australia
2Mechanical engineer, aerospace industry performing structural and
thermal analyses and design
3Langara College, Vancouver, B.C. Canada.
2tonyszamboti@comcast.net and 3old.johns@gmail.com
Received on 22 Dec 2012, Accepted on 8 March 2013
ABSTRACT
This article elaborates on variables associated with the collapse of the
North Tower of the World Trade Center. The previously published
quantifications of inertia, column capacity, and the assumptions
related to the beginning of downward motion, are examined and
corrected. The reasons for false conclusions reached in several previous
analyses are presented.
Key words: Large Deflections, Plasticity, Collapse

1. INTRODUCTION

This presentation is not so much about how the WTC towers failed, but about how they could
not fail. The objective is to eliminate erroneous concepts supported by false assumptions and
by the use of incorrect values for velocity, mass, and column resistance. The only complete
hypothesis of the global collapse mechanism of the Towers is a successive flattening of
stories associated with compressive column failure and referred to as a Progressive Column
Failure mode or PCF in brief. (In the past this mode was often referred to as pancaking, but
this term is not used here to avoid ambiguities). It is explained here why PCF could not be
the mode of the ultimate destruction. The previously published material is quoted and the
new points are brought up. Appendix C can be of interest to those who want a broader
description of facts associated with the collapse. The available information relating to the
kinetics of the collapse is summarized first.

2. THE FIRST PHASE OF DOWNWARD MOTION

Agood comparison between various collapse models and reality makes it necessary to have some
observations of the towers during collapse. To our knowledge, the most accurate and reliable data
available are provided by video footage taken by Etienne Sauret [7], and used in the documentary
film WTC: The first 24 hours. This footage clearly shows the top of WTC 1, including the roof
line, for about the first 3.2 seconds of the collapse. Each pixel represents 0.27 m of the tower, and
the frame rate is 30 per second, allowing for fairly accurate measurements of the motion. It is
International Journal of Protective Structures – Volume 4 · Number 2 · 2013 117
*Corresponding author. E-mail address: ggg@bigpond.net.au
unfortunate that the roof line is visible for only 3.2 seconds before disappearing into a dense cloud
of debris, but these few seconds are, in fact, quite informative.
Now, let us have a look at the numerical values. The velocity of the falling roof of the
North Tower was measured in [7] and the initial phase over the first 1.4 seconds is shown in
Figure 1.
The averaged acceleration during the early phase of the fall (shown as the slope of the
velocity curve in Figure 1) was approximately 5.11 m/s2. The resulting velocity after 1.2 seconds
of the fall, which is the approximate time for a fall of one story (3.7 m), is 6.13 m/s (13.71 mi/h).
For comparison, we note that a free drop (acceleration of 9.81 m/s2) of an object from a height
of 3.7 m takes 0.869 s and the peak velocity reached then is 8.52 m/s. The total height of the tower
was 417 m and the time needed for a free drop from that height was 9.22 s, while the end velocity
of the dropping object would reach 90.45 m/s. If the drop is counted to only the top of mezzanine,
at 21.33 m above ground (a notional top of the rubble heap), then the time is only 8.98 s.

3. COLUMN RESISTANCE IN LARGE-DEFLECTION COMPRESSION

The upper limit of compressive strength of steel columns is usually taken as Py = AFy, where
Fy is the yield strength and A is the section area. This value is reduced to the buckling load
Pcr, according to column slenderness [14]. However, if the columns are stout, as in the case
here, the difference between Py and Pcr is usually quite small. The peak resistance is
encountered at the outset, when a column is straight.
One of the methods used to assess the resistance offered by a slender column past the
elastic range is to treat it as a three-hinge mechanism as done by Bazˇant [1, 2]. The resisting
force decreases with deflection until the two arms of the mechanism become horizontal. At
that point there is a minimum resisting force, which is only a small fraction of its initial Pcr.
One can expect reasonable results from such a mechanism in a slender column, but only in
the early stages of deflection. When interactions between the walls of a column develop,
secondary resistance arises.
Because the columns in the WTC towers were stout by any criterion, one can expect that,
in the large deformation range, the columns would exhibit a minimum resistance being a
significant fraction of Pcr. Consequently, Szuladzn! ski [3] employed the same approach, as
that of Bazant described above, except that he placed a higher estimate on the resisting
capability of columns. With this, he concluded that arrest of the downward motion would
take place quite promptly, just outside the zone affected by the aircraft impact.
118 Some Misunderstandings Related to WTC Collapse Analysis
1
0
−1
−2
−3
−4
−5
−6
−7
−8
0 0.2 0.4 0.6 0.8
Seconds
y = −5.1081 × + 0.3407
R2 = 0.9899
Velocity (m/s)
1 1.2 1.4 1.6
Figure 1. Measured initial velocity of the North Tower fall
A further insight into the level of resistance by stout columns was offered by
Szuladzin! ski [5], who conducted a FEA simulation of a large deflection squashing of a
rectangular, hollow section column (RHS). If Pav designates the average resistance, the
result can be written as
Pav = $ Pcr (1)
where Pcr is the buckling load and $ is the retention factor. For the examined RHS it was
found that $ = 0.4, which was more than assumed in [3]. Prior to that, a square hollow section
(SHS), was used in a simulation of a large-deflection squashing, Ref.[10]. The retention
factor there was not less than $ = 0.665, with this figure related to the use of the minimum,
not the enhanced value of Fy. (In this and the previous example the material was treated as
strain-rate insensitive, but there was some increase in the apparent strength due to dynamic
application of the compressive load.)
Another study, conducted by Korol [4a], involved closed- and open-section beams. Using
semi-experimental formulas by Wierzbicki and Abramowicz [4b] it showed the resistance
levels in the $ = 0.4 range or somewhat below. It is anticipated that thinner open-section
beams may have $ < 0.4, and probably closer to $ = 0.3. A detailed calculation of the
nominal column strength of the assembly and the expected resistance is provided in
Appendix A.
The above estimates are conservative, as they do not take one important factor into
account.
When the vertical deflection exceeds some 2/3 of the length, the walls of a column are
folding and leaning on one another and possibly on the floor. As the process continues and
deflection progresses, it leads to quite large resisting forces being developed. The
simulations done so far were not usually carried out to large enough deflections to take full
advantage of this effect.
Buildings are designed against gravity and lateral loads. Column-and-slab structures are
not very efficient in resisting the second loading type, as the lateral forces cause differential
bending of columns. For this reason, much more material is used in designing columns than
would be needed for resisting gravity alone. When progressive collapse is considered, only
gravity is involved, which means that there is a large safety factor against purely
gravitational loads. This is the reason why a complete failure according to the PCF mode is
generally not a practical proposition. This is not to say that the mode could not occur during
a small part of the collapse, followed by an arrest.
The calculation of movement and arrest mentioned previously (Ref.[3]) referred to the
core alone and was based on a certain load distribution between the core and the outer shell.
That work was therefore limited, because the original PCF concept was for the building as a
whole. Additionally, not all relevant details were established at the time. For this reason a
global approach will be presented below.

4. QUANTIFICATION OF PROGRESSIVE COLLAPSE IN PCF MODE

The National Institute of Standards and Technology (NIST) determined that the North Tower
failure initiation occurred at the 98th story [9], putting the upper section size at 12 stories. The
actual mass of this 12 story section can be found in the NIST report (NCSTAR 1-6D, p. 176,
Table 4–7), which states the actual total load on the columns between floors 98 and 99 to be
73,143 kips, i.e. 325.4 × 106 N or 33.18 × 106 kg. This is corroborated by the independent
analysis shown in [8].
International Journal of Protective Structures – Volume 4 · Number 2 · 2013 119
The motion began when the strength of the columns on the critical floor fell just below
the weight those columns were supporting, therefore Pav = W = 325.4 × 106 N. This was an
average strength in the assembly of columns involved. Many of those columns must have
been damaged, bent out of shape and distorted in various ways. Those that were intensely
heated would increase their deviation from straightness. Probably only a minority of columns
retained the straight-line axis. It was not much of buckling in the traditional sense that
followed. It is an open question as to what the characteristics of such columns could be.
However, there is a clue in Fig.1, which indicates near-constant acceleration, typical of nearconstant
resistance. As shown in [3] as well as below, the above Pav is itself only a small
fraction of the undamaged buckling strength, so it seems reasonable to use it, in the first
approximation, as a typical, average resistance along the downward path. (For this reason Pav
was used here rather than Pcr.) The energy absorbed by columns over the first story travel is
then
% = Pav h = 325.4 × 106 N × 3.7 m = 1,204 × 106 N-m.
The potential energy for a one-story drop is:
U = Wh = 325.4 × 106 N × 3.7 m = 1,204 × 106 N-m.
Both quantities are identical, therefore the arrest takes place over the critical story. One
can also choose to be more conservative and degrade the average resistance by another 25%.
Thus, the energy absorbed over the first story travel will be
% = 0.75 Pav h = 0.75 × 325.4 × 106 N × 3.7 m = 903 × 106 N-m.
This time U > %, therefore stopping is not complete over this story and further motion
must be considered. Noting that the gross kinetic energy available to overcome the resistance
of the next story below is
Ek0 = 1,204 – 903 = 301 MN-m
Before further motion continues, there is an energy loss incurred due to the accretion of
the slab. When this is treated as a fully plastic collision, that loss, according to [5] is
(2)
where Mb = 33 × 106 kg is the mass of the descending part of the building and Ms = 2.74 ×
106 kg is the mass of the accreted slab and its tributaries. After substituting, one finds &Ek =
23 MN-m. Consequently, at the outset of travelling down by a further story, the following status
develops. The moving part now has M = (33 + 2.74) × 106 kg = 35.74 × 106 kg and its potential
energy relative to the next floor is U = Mgh = 1,297.3 × 106 N-m. The energy available to
overcome the column resistance is now
Ek0 – &Ek + U = (301– 23.0 + 1,297.3) × 106 = 1,575.3 × 106 N-m.
&E M
M M
M M
M M
E k
s
s b
b
s
s b
k =
+
'
( )* + ,
=
+
'
( )
*
+ ,
1
2 0
2
0 v
120 Some Misunderstandings Related to WTC Collapse Analysis
The energy absorption capacity of undamaged columns is estimated, in Appendix A, as
2,720 MN-m. The NIST report predicts up to 20% of the core columns to be severed or
severely damaged in the North Tower and it is known from observation that approximately
15% of the perimeter columns were severed or severely damaged. To be conservative, the
remaining capacity of the story below the critical one can also be assumed degraded. Even
if only three-fourths of the undamaged capacity is preserved, we are left with 2,040 MN-m.
This is more than the total energy available, 1,575.3 MN-m, which indicates the arrest of
motion during travel along this story.

5. FALSE CONCEPTS STILL CIRCULATING

As mentioned before, one can expect reasonable results from a hinged post-buckling
mechanism if a column is slender and then only in the early stages of deflection. With an
advancing deformation pattern interactions between the walls of a column develop, with this
being strongly marked for stout columns. Yet, the results from said mechanism were taken by
Bazant [2], somewhat naively, to hold over the entire squashing motion. That gave the column
resistance as asymptotically decreasing with deflection, which is an unrealistic proposition.
The main paper proposing the PCF mode [2] had several discussers involved. The closure
of the discussion [15] pointed out a few flaws that crept into the competing analysis [3],
although these flaws had no adverse effects on the results. The defense of the analysis
presented in [2], on the other hand, was essentially relying on ignoring the arguments to the
contrary. The gross underestimate of the energy absorption capacity of the squashed column
that resulted is named here as the fatal mistake No.1.
From the above assumption Bazant concluded that after the initiation of failure of the
critical story, the columns in that squashed story offered only negligible resistance. That led
to the assumption that the upper part of the building, above that story, would be in a free fall
until a complete flattening of that story. At the end of the critical story squash the free-drop
velocity is over 8.5 m/s, resulting in a destructive impact. This in turn culminated in [2] as a
conclusion of a quick collapse of the entire edifice. We call this a “vanishing story
assumption” and refer to it as the fatal mistake No.2. (This free-fall assumption was not
openly stated, but there are numerous hints in [1, 2, 6] and [12] implying that it was used in
computational procedure.)
Thus, in 2008, the PCF mode was demonstrated to be an inadequate explanation of the
building collapse. Yet, some insist on ignoring the numbers. A recent publication [6] implies
that [2] was entirely correct and says: The collapse of the World Trade Center towers was
initiated by the impact of the upper part falling onto the underlying intact story. The use of
Eq.1 in [6] amounts to assuming a free drop, by one story.
This free drop is inconsistent with a generally agreed scenario, according to which during
the initiation of the collapse the strength of the critical story had to be gradually weakened
by fire to the point where its strength was reduced to being unable to carry the weight above.
From then on the resistance of the buckled columns was gradually decreasing, but would still
be significant with respect to the load above them.
When a calculation consistent with a PCF is made, as demonstrated above, the impact
velocity drops to a small value indicating an arrest or nearly so, so there is no need to explain
an abrupt impact as attempted in Note [6]. A small change in the velocity of the downwardmoving
mass on such impact is a trivial point, as the reader may find above comparing &Ek
resulting from such an impact with the initial potential energy U. Thus, there is no need to
write a paper to explain why that contact of the upper and the lower part of the building was
not noticeable on the video records. This observation removes the whole premise of Note [6].
International Journal of Protective Structures – Volume 4 · Number 2 · 2013 121
To keep in contact with reality, one should note that Fig.1 shows the measured velocity
developed at the end of the fall over the critical story to be much larger (6.13 m/s) than the
speed implied by the PCF mode. This is simply another indication that PCF is not a proper
explanation of the process.
What the authors of [2] and [6] clearly failed to appreciate was the difference between the
softened structure and a vanished structure. One should also note that if there were any
grounds to assume the concept of a “vanishing story” as true, the arrest of motion would still
be concluded, although after a longer travel.
Another problem with [2] is the lack of transparency in showing the reader how the results
were obtained. In a way, the paper is a display of mathematical brilliance by formulating
several arrays of differential equations. There are a few clues given as to how those equations
could be solved, but nothing is said on how the solution was actually obtained. The author
says that for a typical tower configuration the fall time is 10.8 s (vs. 9.21 s for a free fall).
For all of the wide range of parameters (including a structure stronger and lighter than the
real one) the fall time was reported to be less than 18.4 s. This sounds strange, when
considering the results of a more recent work [5], where the calculated time was 15.3 s while
assuming no resistance from columns. The conclusion from all of this is that the results of
[2] were, at best, grossly in error because of the flaws mentioned earlier, or, at worst,
processed to match the lower bound of the observed fall time.

6. CRITERIA FOR VERTICAL BUILDING COLLAPSE, BASED ON COLUMN
FAILURE

Two criteria must be met for any transient, dynamic event that changes the state of the system
to take place. The first is the presence of a big enough force to make that change possible. The
second states that there must be enough energy supplied to enable the change of state. This
collapse is no exception. The first criterion says the gravity force acting on the top part of the
building must be slightly larger than the strength of the story below that top part. (Or, that a
story must have been weakened to a degree meeting that condition.) The second one comes
from the energy balance and determines how long that collapse will last. It says that collapse
will continue as long as the kinetic and potential energy of the downward-moving portion of
the building exceeds the energy-absorption capacity of the columns of the story below.
The texts of the criticized papers mention both criteria, although in a confused manner. In
[2], a statement on p.311 tells the reader that, in fact, the energy criterion renders the strength
criterion irrelevant. The conclusions echo that by saying: What matters is energy, not the
strength, nor stiffness. Confronted with the results of discussion [3], showing a prompt arrest,
Bazant took a small step backward in Closure [15] by saying that the strength criterion was
valid in statics, but not in a dynamic environment, where inertia forces are involved. Thereby
the author missed the fundamental point, namely that the initiation of motion took place in a
static environment and therefore meeting the strength criterion was indispensable.
(Dynamics enters later, when significant accelerations or inertia forces are developed.)
Conclusion: The results were obtained while ignoring the strength criterion and are therefore
invalid on this count alone. (This was a visible confusion between statics and dynamics and
is regarded here as the fatal mistake No.3.)

7. OTHER PROBLEMS WITH THE HYPOTHESIS OF PCF MODE

It is difficult to understand why the inflated mass of 54.18 x 106 kg was used in [2] and [6],
and an even larger value of 58 × 106 kg applied in [1], when the per-floor mass was correctly
described in the addendum to [1], and also, when one of the authors was common to all three
papers. In that addendum the mass of 44% of the whole tower was calculated as 141 × 106 kg
122 Some Misunderstandings Related to WTC Collapse Analysis
using a modal frequency analysis. This equates to 320.45 × 106 kg for the whole tower. When
this mass is divided by 117 floor levels (for 110 above-ground stories, 6 sub-levels, and the
roof) it gives a single floor mass of 2.74 × 106 kg. Multiplying this per floor mass by the
12 stories in the upper part of the North Tower gives it a mass of approximately 33 × 106 kg.
Let us designate the kinetic energy at first impact by K and the energy absorption
capacity of the columns by %. When the velocity is corrected from 8.52 to 6.13 m/s, the
mass from 58 × 106 kg to 33 × 106 kg, and % from 500 MN-m to a minimum of 1,686 MNm
as shown in Appendix A , the value of K/%min, given implicitly as 4.2 in Ref. [1] for a
one story fall, is found to be significantly lower, namely 0.368. A gross over-estimate of the
relative magnitude of the kinetic energy available vs. column energy absorption capacity
was the reason for concluding in [2] that the motion of the upper part was unstoppable.
As one can readily see, this mode of damage is a distinct process, whereby each floor
becomes crushed, one after the other. An attempt has been made to smear the process out into
a continuum event and then use differential equations to obtain a solution [2]. Yet,
justification of such an approach must be performed, by showing that little is lost in
translation. As no such justification exists, the whole approach in [2] seems questionable.

8. SUMMARY

A number of simple, transparent calculations of the North Tower collapse were presented in
[5] and the conclusion was that assuming even a modest resistance of columns during their
destruction would cause an unacceptably long collapse time. It is only when perfectly
frangible columns were adopted that the fall time was as low as 15.3 s. This removes the PCF
mode, as defined here, as a viable hypothesis of collapse.
Yet, the PCF achieved significant popularity, as based on [1] and [2], while the next work
[12] did not contribute anything new to the core of the subject. These papers, purporting to
explain the collapse, suffered from three fatal errors, as detailed above. Also, the whole
methodology was not justified. Some incredibly short fall times were quoted by the authors,
while all solutions were of a black-box type. The presentations in these papers are not a valid
description of what happened. The reasons for a smooth motion history and promptness of
collapse of the North Tower remain yet to be determined.
REFERENCES
[1] Bazˇant, Z.P. and Zhou, Y, “Why Did the World Trade Center Collapse?—Simple Analysis”. Journal of
Engineering Mechanics, Vol.128, No.1, pp.2–6, January 2002.
[2] Bazˇant, Z.P. and Verdure, M., “Mechanics of Progressive Collapse: Learning from World Trade Center and
Building Demolitions”. Journal of Engineering Mechanics, Vol.133, No.3, pp.308–319, March 2007.
[3] Szuladzin´ski, G. Discussion of “Mechanics of Progressive Collapse: Learning from World Trade Center and
Building Demolitions” by Z.P. Bazant and M. Verdure. Journal of Engineering Mechanics, ASCE, Vol.134,
No.10, Oct.2008, pp.913–915.
[4a] Korol, R.M., “Collapse Time Analysis of Multi-Story Structural Steel Buildings”. The Open Civil
Engineering Journal, 2011, 5, pp.25–35.
[4b] Wierzbicki, T. and Abramowicz, W., “The mechanics of deep plastic collapse of thin-walled structures”. Part
of T. Wierzbicki, and N. Jones, Eds, Structural failure, vol. 9. John Wiley, 1989, pp. 281–329.
[5] Szuladzin´ski, G. “Temporal Considerations in Collapse of WTC Towers”.Int. J. Structural Engineering, Vol.
3, No. 3, Feb 2012, pp.189–207.
[6] Ja-Liang Le and Bazˇant, Z.P., “Why the Observed Motion History of World Trade Center Towers is Smooth”.
Journal of Engineering Mechanics, Vol. 137, No. 1, January 1, 2011, pg. 82–84.
[7] Chandler, D. (2010). “Destruction of the World Trade Center North Tower and Fundamental Physics”,
Journal of 9/11 Studies, available at http://www.journalof911studies.com.
International Journal of Protective Structures – Volume 4 · Number 2 · 2013 123
[8] Urich, G. (2007). “Analysis of the Mass and Potential Energy of World Trade Center Tower 1”, Journal of
9/11 Studies, available at http://www.journalof911studies.com.
[9] National Institute of Standards and Technology (NIST). (2005). Final report on the Collapse of World Trade
Center Towers NIST-NCSTAR 1, NIST, Gaithersburg, Md.
[10] Analytical Service Pty Ltd. Large-deflection squashing of a steel column. Technical Note No.56, November
2008.
[11] Bazˇant, Z. P., and Cedolin, L. Stability of structures: Elastic, inelastic, fracture and damage theories, 2nd
Ed., Dover, New York, 2003.
[12] Bazant, Z.P., Le, J.-L., Greening, F.R., and Benson, D.B. (2008). “What did and did not cause collapse of
World Trade Center twin towers in New York?”. J. of Engrg. Mechanics ASCE 134 (10) 892–906.
[13] Kennedy, K. and Rahman, N. Strength tables for special seismic and blast design of cold-formed steel
connections. The Steel Network, Durham, NC 27709, USA. Updated Jan. 2012.
[14] Szuladzin´ski, G. Formulas for mechanical and structural shock and impact. Page 463. CRC Press, 2009.
[15] Bazˇant, Z.P. and Jia-Liang Le. Closure to “Mechanics of Progressive Collapse: Learning from World Trade
Center and Building Demolitions” by Bazˇ ant, Z.P. and Verdure, M., Journal of Engineering Mechanics,
Vol.133, No.3, pp.308–319, October 2008.
[16] Bazant, Z.P. Closure to “Why the Observed Motion History of World Trade Center Towers Is Smooth” by
Jia-Liang Le and Z.P. Bazant . Journal of Engineering Mechanics, ASCE, Vol.138, No.10, pp. 1300–1301,
October 2012.
[17] Grabbe, C. Discussion of “Why the Observed Motion History of World Trade Center Towers Is Smooth” by
Jia-Liang Le and Z.P. Bazant . Journal of Engineering Mechanics, ASCE, Vol.138, No.10, pp. 1298–1300,
October 2012.
[18] Links to NBC videos: http://www.youtube.com/watch?v=MgJ7t5D9gTk and http://www.youtube.com/
watch?v=y9-owhllM9k.
APPENDIX A. ESTIMATED STRENGTH OF COLUMNS
The columns of the outer shell of the building were square hollow sections (SHS) of 356 mm
(14’’) side length. At the 98th and the 97th floors the wall thickness was 6.9 mm (0.270”) and
the yield strength was 65 ksi (448.3 MPa) according to the NIST report. There were 240 such
columns and their total cross-sectional area was 2.296 m2. The yield load was thus
Py1 = 448.3 MPa × 2.296 m2 = 1,029 MN
The core columns at the 98th and 97th floors had the total sectional area of 2,621 in2 or
1.69 m2. (This was summed from the released NIST SAP2000 data). There were a variety of
steel grades used: 36, 42, 45 and 50 ksi yield strength. Taking 42 ksi (290 MPa) as
representative, the yield load was
Py2 = 290 MPa × 1.69 m2 = 490 MN
The total yield load is the sum of the above: Py = Py1 + Py2 = 1,029 + 490 = 1,519 MN
The columns are stocky enough, so that a small reduction in strength, when going from yield
load to buckling load can be ignored, so that we have Pcr - 1,519 MN on a static basis.
A minimum column energy absorption capacity, over a fall through one floor height, can
be calculated with $ = 0.3 as
Pave = 0.3 × 1,519 MN = 455.7 MN
%min = 455.7 MN × 3.7 m = 1,686 MN-m
124 Some Misunderstandings Related to WTC Collapse Analysis
To comport with reality, the yield load of 1,519 MN will be adjusted upwards by two
factors. The first is the dynamic load factor taken as 1.1. The second is the benefit of the
difference between minimum guaranteed values and the likely expected values, modestly
assumed to also be 1.1. (In designing safe structures, the guaranteed minima are the right
thing to use. However, for these steel types the tested yield strength is typically larger or
much larger than the guaranteed values. If the objective is to find what happened, the most
likely number must be used.)
To explain the above: The first factor was used to account for the dynamic strength of the
steel. The load applied during impact would have been dynamic in nature and it is well
understood that the elevated strain rate acts to increase the apparent yield strength. The
second factor was used to account for actual yield strength as opposed to minimum values,
as explained in the text. The actual values of the Twin Tower column materials were reported
by [9], 1–6, Table 4–1, p. 61 to be well above the minimum guaranteed strength. Table 1 of
the attached Tech Note [13] shows suggested increase factors (naming them DIF and SIF
respectively) to be used for cold-formed steel design as recommended by two different
ASCE publications and the DoD UFC 3-340-02.
Therefore, the total estimated buckling strength of the 97th floor columns would have been
P’cr = 1,519 MN × 1.1 × 1.1 = 1,838 MN
Most columns under consideration had the SHS section for which the strength multiplier,
as noted before was expected to be $ = 0.5. However, most core columns had open sections,
for which a smaller value would be expected. To be on the safe side, one can take $ = 0.4 for
all columns on the floor. Consequently, the strain energy absorption over the 3.7 m travel
would be
% = 0.4 P’cr × 3.7 m = 2,720 MN-m
APPENDIX B. DIMENSIONALITY OF BUILDING COLLAPSE
There have been opinions stated by some claiming that a one-dimensional analysis such as
the one presented here are not valid, because they do not include the lateral effects of the
collapse, effects that were quite visible during the catastrophe. One example of such criticism
is provided by Grabbe [17], who notes that there was a significant lateral ejection of dust,
debris and structural fragments.
When we observe the collapsing North Tower, the downward motion seems to be quite
regular in the sense that all points on the building surface move down by about the same
amount in a given time period. This invites a unidirectional analytical treatment. On the other
hand, the lateral effect mentioned can’t be ignored, because
(a) Ejection of gas and debris causes the loss of mass and energy of the falling building.
(b) Expulsion of air, until fully accomplished, tells us that there is an air cushion in action.
Both (a) and (b) have the effect of slowing down the falling part of the building. Yet, in
spite of this, the lateral action is only a minimal secondary effect. Perhaps the most rational
way out of the difficulty is to say that the event is essentially one-dimensional, but the results,
especially the duration of fall, need an adjustment to account for the lateral effects.
The problem is not unlike that of a steel column squashed vertically between two guided
plates. In a large-deflection mode a good part of the column material will move sideways.
Yet, the overall behavior can be quantified as uni-dimensional: Axial load vs. axial
displacement.
International Journal of Protective Structures – Volume 4 · Number 2 · 2013 125
One must observe that we know about uniform vertical movement only during the time
the upper part of the building is visible and before it disappears in a cloud of dust. Later on,
large structural elements can be seen falling from inside the cloud. This may suggest a loss
of symmetry in the event, but then the process might have been advanced enough by that
point, so that accurate preservation of symmetry may not have mattered.
APPENDIX C. THE SEQUENCE OF THE INITIAL COLLAPSE
The event may be summarized as follows. On September 11, 2001, the North Tower was
impacted by a Boeing 767 airliner, which literally flew into the building. There was an
immediate explosion followed by prolonged fires, which were ignited and possibly
continuously fed by an estimated 38,000 liters of fuel which had been on board the aircraft
(there is not unanimous agreement as to how long the fuel would have been available to
sustain the fires. The NIST report and some researchers postulate that it would have burned
up within minutes of the aircraft impact and thus only served to ignite the fires). After 1 hr
and 42 min had elapsed, from the time of impact, the entire building collapsed, in a
progressive downward movement, beginning at the 98th floor.
From an engineering viewpoint the event had many fascinating aspects. Not the least of
them was “the aircraft flying into the building” mentioned above. This means the aircraft
structure cut the building structure on its way. The aircraft was built of an aluminum shell on
the order of 2 mm thickness, which was additionally stiffened by longitudinal and lateral
elements. At contact with the building the fuselage was pitched nose down by 10.6° and hit
the building between the 95th and 96th floors. There was a 25° roll, so one wing impacted a
higher part of the building than the other. The exterior columns in the area of impact had 6.9
mm thick hollow square sections of 356 mm side length. Yet, the thin aluminum wings cut
through the much thicker steel. The aircraft would have certainly suffered severe unspecified
fractures in the process. An analysis by NIST shows the wings would have largely been
disintegrated while going through the exterior wall, but that the fuselage would continue
along its path with enough speed to damage some core columns on its way between the 94th
to 96th floor levels. The 98th floor, where the collapse initiated, was at the edge of the impact,
and was only hit by a wing tip and would have suffered no core column damage.
The Sauret video [7] quoted before is the best visual record that we have of the early phase
of the fall of the North Tower as seen from the north side. It allows us, along with an NBC
video [18], showing the west side, to quantify visible downward motion of the northeast,
northwest, and southwest roofline corners. Measurements show them falling within 0.25 to
0.50 seconds of each other in a nearly straight downward collapse of the upper part of the
building. This continues for at least two stories, after which a tilt angle of about 8 degrees
southward appears while the top part of the building continues its fall. During the measurable
fall, the roof is moving downward at a constant acceleration, much larger than Pave of
columns heated to failure would allow.
The NIST report claims that the south exterior wall failed, as a result of prolonged heating
of the attached floor trusses on that side, and that this caused a propagation of failure across
the 98th floor resulting in a vertical drop, but they do not analyze the spread of failure in
either the horizontal or the vertical directions. They do provide the load redistribution from
this south wall failure, but that does not generate loads big enough to fail the remaining
columns across the floor. Bazant [2] does not explain the initial propagation of failure across
the 98th floor in any of his analyses, other than to assume uniform heating and collapse. The
reasons for the evenness of the initiation at the 98th floor and straight down fall in spite of
asymmetric damage, the smooth motion history while falling through successive floors, and
the promptness of collapse of the North Tower, remain yet to be explained.

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.